S. Darakshan, S.P. Wani and V. Raghavan
Food Research and Analysis Center (FRAC), Delhi, India.
J Pure Appl Microbiol. 2012;6(1):471-473
© The Author(s). 2012
Received: 15/07/2011 | Accepted: 28/09/2011 | Published: 31/03/2012
Abstract

Most probable number (MPN) test was done to detect the coliforms in water samples collected from North, South, East, West and Central Delhi. The study revealed that the number of coliforms was very high (_1600) in water samples collected from North, South and East .The bacteria were identified as Escherichia coli. Bacteriological examination of water samples collected from different sources showed that the MCD water of North, South and East Delhi was found to be contaminated while as MCD Water of West and Central Delhi was safe for Drinking Purpose.

Keywords

Drinking water, Coliform, MPN test

Article Metrics

Article View: 833

Share This Article

© The Author(s) 2012. Open Access. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License which permits unrestricted use, sharing, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.